S5 Duty Cycle Technical Data
Stages
|
Ratio
|
T2N
(Nm)
|
T2max
(Nm)
|
T2E(1)
(Nm)
|
N1n
(min-1)
|
N1max
(min-1)
|
F2Amax
(N)
|
F2Rmax
(Nm)
|
η
%
|
M
(kg)
|
Δφ
(arcmin)
|
---|
1
|
4
|
3300
|
5300
|
12000
|
1000
|
2000
|
64000
|
86000
|
≥97
|
110
|
≤3
|
---|
5
|
3300
|
5300
|
12000
|
1000
|
2000
|
64000
|
86000
|
≥97
|
110
|
7
|
3300
|
5300
|
12000
|
1000
|
2000
|
64000
|
86000
|
≥97
|
110
|
10
|
2200
|
3700
|
10000
|
1000
|
2000
|
64000
|
86000
|
≥97
|
110
|
2
|
16
|
2750
|
5300
|
12000
|
1000
|
2000
|
64000
|
86000
|
≥94
|
120
|
≤3
|
---|
20
|
3300
|
5300
|
12000
|
1000
|
2000
|
64000
|
86000
|
≥94
|
120
|
25
|
3300
|
5300
|
12000
|
1000
|
2000
|
64000
|
86000
|
≥94
|
120
|
28
|
3300
|
5300
|
12000
|
1000
|
2000
|
64000
|
86000
|
≥94
|
120
|
35
|
3300
|
5300
|
12000
|
1000
|
2000
|
64000
|
86000
|
≥94
|
120
|
40
|
3300
|
5300
|
12000
|
1000
|
2000
|
64000
|
86000
|
≥94
|
120
|
50
|
3300
|
5300
|
12000
|
1000
|
2000
|
64000
|
86000
|
≥94
|
120
|
70
|
3300
|
5300
|
12000
|
1000
|
2000
|
64000
|
86000
|
≥94
|
120
|
100
|
2200
|
2500
|
10000
|
1000
|
2000
|
64000
|
86000
|
≥94
|
120
|
(1) T2E Up to 1000 times during the gearbox's lifetime
Subject to technical improvements without prior notice
General Data
Housing Surface Temperature
|
°C
|
-10°C a +90°C
|
---|
Ingress Protection
|
|
IP65
|
---|
Sound Levels
|
dB(A)
|
≤70
|
---|
Design Life
|
Hours
|
20000
|
---|
Lubrication
|
|
Lifetime Grease Lubrication
|
---|
Turning Direction
|
|
Same as Input
|
---|
Moment of Inertia
Stages
|
Ratio
|
J (kg·cm2)
|
---|
1
|
4
|
300
|
---|
5
|
230
|
7
|
160
|
10
|
130
|
2
|
16
|
69
|
---|
20
|
56
|
25
|
54
|
28
|
61
|
35
|
51
|
40
|
39
|
50
|
38
|
70
|
38
|
100
|
37
|