S5 Duty Cycle Technical Data
Stages
|
Ratio
|
T2N
(Nm)
|
T2max
(Nm)
|
T2E(1)
(Nm)
|
N1n
(min-1)
|
N1max
(min-1)
|
F2Amax
(N)
|
M2Kmax
(Nm)
|
C
(Nm/arcmin)
|
η
%
|
M
(kg)
|
Δφ
(arcmin)
|
---|
1
|
4
|
770
|
1100
|
2420
|
2500
|
6000
|
5450
|
1300
|
440
|
≥97
|
31.6
|
≤1
≤3
≤5
|
---|
5
|
840
|
1200
|
2640
|
2600
|
6000
|
5450
|
1300
|
440
|
≥97
|
31.6
|
7
|
770
|
1100
|
2420
|
3000
|
6000
|
5450
|
1300
|
440
|
≥97
|
31.6
|
8
|
700
|
1000
|
2200
|
3000
|
6000
|
5450
|
1300
|
440
|
≥97
|
31.6
|
10
|
370
|
520
|
1150
|
3000
|
6000
|
5450
|
1300
|
440
|
≥97
|
31.6
|
2
|
20
|
770
|
1100
|
2420
|
3000
|
6000
|
5450
|
1300
|
440
|
≥94
|
5450
|
≤3
≤5
≤7
|
---|
25
|
840
|
1200
|
2640
|
3000
|
6000
|
5450
|
1300
|
440
|
≥94
|
5450
|
35
|
840
|
1200
|
2640
|
3000
|
6000
|
5450
|
1300
|
440
|
≥94
|
5450
|
40
|
840
|
1200
|
2640
|
3000
|
6000
|
5450
|
1300
|
440
|
≥94
|
5450
|
50
|
840
|
1200
|
2640
|
3000
|
6000
|
5450
|
1300
|
440
|
≥94
|
5450
|
70
|
770
|
1100
|
2420
|
3000
|
6000
|
5450
|
1300
|
440
|
≥94
|
5450
|
100
|
370
|
520
|
1150
|
3000
|
6000
|
5450
|
1300
|
440
|
≥94
|
5450
|
(1) T2E Up to 1000 times during the gearbox's lifetime
Subject to technical improvements without prior notice
General Data
Housing Surface Temperature
|
°C
|
-10°C a +90°C
|
---|
Ingress Protection
|
|
IP65
|
---|
Sound Levels
|
dB(A)
|
≤67
|
---|
Design Life
|
Hours
|
20000
|
---|
Lubrication
|
|
Lifetime Grease Lubrication
|
---|
Turning Direction
|
|
Same as Input
|
---|
Moment of Inertia
Stages
|
Ratio
|
J (kg·cm2)
|
---|
1
|
4
|
25.03
|
---|
5
|
23.29
|
7
|
22.48
|
8
|
22.48
|
10
|
22.51
|
2
|
20
|
7.42
|
---|
25
|
7.42
|
35
|
7.42
|
40
|
7.03
|
50
|
7.03
|
70
|
7.03
|
100
|
7.03
|